17

6.1.2 Reset Connection 

Scan the “Reset Connection” when switch connection from one PC to another PC. 
The scanner will re-start itself after this barcode is read. 

6.1.3  Authentication & PIN Code 

The 800/850 scanner can do connection authentication if communication security is 
desired. Once this setting is enabled, a user configurable PIN code is verified 
during connection establishment. The scanner will refuse connection if the PIN 
code is incorrect. User can specify up to six characters of PIN code. 

6.1.4  Device Name Broadcasting 

The scanner can be configured to hide itself by NOT broadcasting itself on the air. 
This can avoid unwanted computer/PDA from connecting to the scanner. But for 
the initial (first time) connection setup, this setting must be enabled. User can 
disable this setting for security reasons after initial connection setup is completed. 

6.1.5 Update Settings 

After all the desired settings are completed, the “Update” barcode must be scanned 
to make the new settings effective. The scanner will re-start itself after “Update” 
barcode is scanned. 

 

6.2 

HID Keyboard Interface

  

 

6.2.1 

Keyboard Type

 

The HID keyboard interface is enabled by configuring/selecting keyboard type. 
The supported keyboard types are listed below. 

• 

PCAT - US, French German, Italian, Swedish, Norwegian, UK, Belgium, 
Spanish, and Portuguese KBD 

6.2.2  Keyboard Style - Alphabets 

Keyboard layout style can be selected. There are three options to this setting: 
default layout (US or English style), AZERTY layout, and QWERTZ layout. This 
setting only works when the keyboard type selected is for US keyboard. The 
scanner will make necessary adjustment when sending the ‘A’, ‘Q’, ‘W’, ‘Z’,  ‘Y’, 
and ‘M’ character according to this setting. 

6.2.3  Keyboard Style – Digits 

There are two digit layout styles as shown on the following figures. One has digit 
on top (upper row) of a key and another has digits on bottom (lower row) of a key. 

 

18

The digit layout style can be changed by the following configuration settings. 
There are three options: 

Default

Lower Row

, and 

Upper Row

. The scanner will 

make necessary adjustment when sending digits according to the setting value of 
this parameter. This setting is used with the above setting (Keyboard Style – 
Alphabets) and perhaps Character Substitution setting, when support to languages 
not available on the scanner is needed. 

 

 

6.2.4  Capital Lock Status 

In order to send alphabets with correct case, the scanner needs to know the capital 
lock status of the keyboard. Incorrect settings may result in reversed case of 
alphabets being transmitted. There are 3 options to this parameter: 

On

Off

, or 

Auto 

Detection

. If this parameter is set to 

Auto Detection

, the scanner will automatically 

detect the capital lock status of the keyboard before it transmits data.  

6.2.5 Alphabets Transmission 

User can choose how alphabets are sent by this parameter configuration. The 
alphabets can be sent according to their case (the 

Case Sensitive

 

option), or the 

case is ignored (the 

Ignore Case

 

option) when transmitting. 

6.2.6 Digits Transmission 

User can choose how the scanner transmits digits by configuring this parameter. 
The scanner can transmit digits by using the alphanumeric key or by using the 
numeric keypad. The Num Lock status of the keyboard should be ON if numeric 
keypad option is selected.  

 

 

        

 !           @            #           $  

         

1            2            3           4  

Digits on Lower Row 

        

 1            2            3           4  

         !            @           #           $  

Digits on Upper Row 

Numeric Key Pad 

Alpha Numeric Key 

Summary of Contents for WWS800

Page 1: ...pment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help If applica...

Page 2: ...1 Transmit Buffer Setting 13 4 4 2 Memory Mode 13 4 4 3 Clear Data 13 4 4 4 Send Data 13 4 4 5 Memory Data Delay 13 5 BLUETOOTH SERIAL PORT 14 5 1 CONFIGURING WWS800 850 14 5 1 1 Activate Bluetooth S...

Page 3: ...O FIELDS 32 9 6 ADDITIONAL FIELDS 33 9 7 FIELD TRANSMISSION SEQUENCE 33 9 8 END OF FORMAT PROGRAMMING 33 9 9 ACTIVATE DATA EDITING FORMATS 33 9 10 EXCLUSIVE DATA EDITING 34 9 11 PROGRAMMING EXAMPLES 3...

Page 4: ...n be reorganized according to user programmable formats Up to three data editing formats are supported Extremely Low Power Consumption 2 2 Base Installation The WWS800 850 kit contains A WWS800 850 wi...

Page 5: ...abel the scanner will beep once then scan the SERIAL number barcode The scanner will beep twice low then high When it establishes RF connection with the base the scanner will then emit three short asc...

Page 6: ...eep The scanner will issue a long beep with a low tone to indicate errors Enter Exit Configuration Beep The scanner will issue 6 beeps upon entering exiting the configuration mode Setup Beep In config...

Page 7: ...the scanner to start scanning once a barcode is brought within Range of the scanner This will activate the LEDs and the scanner will start decoding the barcode The auto sense mode works only under Au...

Page 8: ...below PCAT US French German Italian Swedish Norwegian UK Belgium Spanish and Portuguese KBD PS2 30 IBM 3477 TYPE Japanese KBD IBM 34XX 319X Memorex Telex 122Keys 4 1 2 Keyboard Style Alphabets Keyboa...

Page 9: ...RS232 Interface User can select the desired flow control baud rate parity and data bits to be used in this output interface 4 2 1 Baud Rate Parity Data Bits The supported baud rate parity and data bit...

Page 10: ...section illustrates a step by step installation and configuration procedures of the WWS800 850 for Bluetooth Serial Port Bluetooth transceivers dongles always come with their own driver or Windows XP...

Page 11: ...e unit however a charging dock is still needed for charging the 800 850 battery This section illustrates a step by step installation and configuration procedures of the 800 850 for Bluetooth HID Bluet...

Page 12: ...e scanner will make necessary adjustment when sending the A Q W Z Y and M character according to this setting 6 2 3 Keyboard Style Digits There are two digit layout styles as shown on the following fi...

Page 13: ...ections 6 3 1 Windows XP with Service Pack2 1 Insert the Bluetooth dongle into PC host 2 Double click the Bluetooth icon on the lower right of the taskbar 3 Click Add button 1 Check My device is set u...

Page 14: ...comm Bluetooth Driver 1 Click icon at PC 2 Click Find Bluetooth Devices icon at My Bluetooth Places 22 3 Right click the 800 850 scanner and select Pair Device 4 Input PIN code and click OK button 5 R...

Page 15: ...g transmitted 7 2 Italy French Pharmacode For Italy French Pharmacode there is always a checksum character included in the barcode So the checksum verification is always performed when decoding these...

Page 16: ...ng Because of the way system number 1 is encoded if both system numbers are enabled user might suffer from short scanning UPCA or EAN13 into UPCE system number 1 barcodes Convert to UPCA If this param...

Page 17: ...selected the max length and the min length must be specified and the scanner will only accept those codes with lengths fall between max min length specified 7 10 Plessey Convert to UK Plessey If this...

Page 18: ...ngth Code or any Additional Field and is performed before editing mode processing If only the character to be replaced is specified every occurrence of that character in the barcode will be taken away...

Page 19: ...not be performed unless all three applicable conditions are met The configurable applicable conditions are described below Code Type This parameter specifies the code type of the data eligible for da...

Page 20: ...n the Editing Format Parameters section of the configuration manual 9 9 Activate Data Editing Formats Before data can be processed by a particular editing format that format must be enabled The editin...

Page 21: ...or most of the parameters only one read is required to set them to new values The scanner will respond with two beeps when these parameters are configured But for some special parameters multiple read...

Page 22: ...are the scan code value of the character being programmed Add Shift The Shift key will be sent together with the character programmed 38 Add Control L The left Control key will be sent together with t...

Reviews: