23
6. Click
PC Remote Commander
icon.
7. Click
Yes
Button.
8. When the green arrow icon is displayed, the connection is ready.
No
24
7. Symbology Parameters
This section describes user configurable parameters that are pertaining to barcode
symbologies.
7.1 Code39
•
Standard / Full ASCII Code 39
: User can choose to read either Standard
Code 39 or Full ASCII Code 39 by configuring this parameter.
•
Start/Stop Transmission
: This parameter specifies whether the start/stop
characters of Code 39 are included in the data being transmitted.
•
Checksum Verification
: This parameter specifies whether the scanner will
perform checksum verification when decoding barcodes. If the checksum is
incorrect, the barcode will not be read.
•
Checksum Transmission
: This parameter specifies whether the checksum
characters are included in the data being transmitted.
7.2 Italy / French Pharmacode
For Italy /French Pharmacode, there is always a checksum character included in the
barcode. So the checksum verification is always performed when decoding these
symbologies. User though can choose whether the checksum character is to be
transmitted or not. The start / stop transmission of this code shares the same setting
of Code 39.
•
Checksum Transmission
: This parameter specifies whether the checksum
character is included in the data being transmitted.
7.3 Industrial / Interleave / Matrix 25
•
Start / Stop Selection
: This parameter provides the readability of all 2 of 5
symbology variants. For example, flight tickets actually use an Industrial 25
barcode but with Interleave 25 start / stop. In order to read this barcode, the
start / stop selection
parameter of Industrial 25 should set to ‘
Interleave
25
.
•
Checksum Verification
: This parameter specifies whether the scanner will
perform checksum verification when decoding barcodes. If the checksum is
incorrect, the barcode will not be read.