AY-Q6x50 Family 

Anti-Vandal MIFARE Contactless 

Smart Card / PIN Readers

 

Installation and Programming Manual 

 

Models:

 

AY-Q6250 
AY-Q6350

AY-Q6250 

AY-Q6350 

Summary of Contents for AY-Q6250

Page 1: ...AY Q6x50 Family Anti Vandal MIFARE Contactless Smart Card PIN Readers Installation and Programming Manual Models AY Q6250 AY Q6350 AY Q6250 AY Q6350 ...

Page 2: ...al property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give t...

Page 3: ...tical Back Tamper 14 5 Keypad Programming Instructions AY Q6350 15 5 1 Transmit Mode 15 5 2 LED Control 15 5 3 Programming Menu 15 5 4 Entering Programming Mode 17 5 5 Exiting Programming Mode 17 5 6 Selecting Keypad Transmission Format 18 5 7 Keypad Transmission Format Option Number 19 5 7 1 Single Key Wiegand 6 Bit Rosslare Format 19 5 7 2 Single Key Wiegand 6 Bit Nibble Parities 20 5 7 3 Single...

Page 4: ...t Option Number 24 5 9 1 Wiegand 26 Bit 24 5 9 2 Clock and Data 25 5 9 3 Wiegand Card PIN Transmission Format 25 5 9 4 Wiegand 26 Bit and Facility Code 25 5 9 5 Wiegand 32 Bit 26 5 9 6 Wiegand 32 Bit Reversed 26 5 9 7 Wiegand 34 Bit 26 5 9 8 Wiegand 40 Bit and Checksum 27 5 10 Changing the Programming Code 27 5 11 Changing the Facility Code 28 5 12 Setting the Backlight 28 5 13 Return to Factory D...

Page 5: ...List of Figures AY Q6x50 Family Installation and Programming Manual v List of Figures Figure 1 Back Plate 11 Figure 2 Connecting the Reader to an Access Control System 13 ...

Page 6: ...List of Tables vi AY Q6x50 Family Installation and Programming Manual List of Tables Table 1 Wiring Colors 12 Table 2 Programming Menu 16 Table 3 Keypad Transmission Formats 19 ...

Page 7: ... future options Therefore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent noncompliance damage or injury The text images and graphics contained i...

Page 8: ...t allow multiple card and keypad transmission formats thus providing a high level of compatibility and connectivity with host controllers 1 1 Main Features Built in 13 56 MHz ISO14443A 3 smart card reader Programmable card transmission formats Wiegand 26 Bit default Clock Data Wiegand Card PIN Wiegand 26 Bit with Facility code output Wiegand 32 Bit Wiegand 32 Bit reverse output Wiegand 34 Bit Prog...

Page 9: ...sic 4K bytes memory MIFARE Ultralight 512 bit EEPROM is only partly supported only 32 bits out of the 64 bits can be transmitted 1 3 Box Content Before beginning verify that all of the following is in the box If anything is missing please report the discrepancy to your nearest Rosslare office One AY Q6x50 Reader unit Installation kit including One drilling template label sticker One security splin...

Page 10: ...ble Distance 150 m 500 ft using an 18 AWG cable Max Proximity Read Range 30 mm 1 2 in Frequency 13 56 MHz Transmission Formats Wiegand and Clock Data Card Compatibility MIFARE and all ISO14443A 3 cards Environmental Characteristics Operating Temperature Range 31 C to 63 C 25 F to 145 F Operating Humidity Range 0 to 95 non condensing Suitable for outdoor use meets IP65 Operating Environment Suitabl...

Page 11: ...equired surface and connect it to the access control system 3 1 Mounting Instructions Prior to starting select the location where the unit is to be mounted To mount the reader on a surface 1 Open the unit by loosening and removing the case security screw at the bottom using the security spline key 2 Depending on the type of installation gang box or panel mount drill the respective holes in the rea...

Page 12: ...ew and the special tool supplied with the hardware 3 2 Wiring Instructions The AY Q6x50 is supplied with a 46 cm 18 pigtail comprising six wires To connect the reader to the controller 1 Prepare the unit s cable by cutting the cable jacket back 3 2 cm 1 and stripping the wire 1 3 cm 2 Prepare the controller cable by cutting the cable jacket back 3 2 cm 1 and stripping the wire 1 3 cm 3 Splice the ...

Page 13: ...sed conductors The individual wires from the reader are color coded according the Wiegand standard When using a separate power supply for the reader this supply and that of the controller must have a common ground The reader s cable shield wire should be preferably attached to an earth ground or a signal ground connection at the panel or a power supply end of the cable This configuration is best f...

Page 14: ...ransmitted only the LSB portion of the serial number is transmitted This depends on the reader transmit format of the selected reader and the length of the card serial number For example when the Wiegand 26 bit transmit format is selected the MSB byte of the MIFARE 1K card s serial number is not transmitted 4 2 Optical Back Tamper The AY Q6250 and AY Q6350 includes an optical back tampering mechan...

Page 15: ...re always sent in Wiegand Clock Data or Card PIN Wiegand format see Section 5 8 5 2 LED Control To cause the LED to remain green continuously pull the LED control wire brown to ground black wire If the LED control wire brown is left open the LED behaves as described above Connecting the LED control input to the access control unit s LED control output allows control of the LED color for example it...

Page 16: ...inary Facility Code Wiegand 26 Bit 5 1 to 5 Keys Facility Code Wiegand 26 Bit 6 6 Keys BCD and Parity Bits Wiegand 26 Bit 7 Single Key 3x4 Matrix Keypad 8 1 to 8 Keys BCD Clock Data Single Key 2 Selecting MIFARE Card Transmission Format 1 Wiegand 26 Bit default 2 Clock Data 3 Wiegand Card PIN 4 Wiegand 26 Bit with Facility Code Output 5 Wiegand 32 Bit 6 Wiegand 32 Bit Reverse Output 7 Wiegand 34 B...

Page 17: ...gramming mode The factory default Programming code is 1234 If a Programming code is not entered within 30 seconds the AY Q6350 returns to Transmit mode 5 5 Exiting Programming Mode To exit Programming mode 1 Press You hear a long beep The Transmit LED turns red and the Program LED turns off This indicates that the AY Q6350 has returned to Transmit mode While in Programming mode if no key is presse...

Page 18: ...mber for the keypad transmission format that you wish Three 3 beeps are emitted on success When selecting Option 8 the Program LED turns orange and awaits additional key input selecting the number of keys You hear three beeps The system returns to Transmit mode If an incorrect option number is entered a long beep is sounded the reader returns to Transmit mode and the keypad transmission format rem...

Page 19: ...ity code Wiegand 26 Bit 4 1 to 5 Keys Facility code Wiegand 26 Bit 5 6 Keys BCD and Parity Bits Wiegand 26 Bit 6 Single Key 3x4 Matrix Keypad 7 1 to 8 Keys BCD Clock Data Single Key 8 Option 1 is the default factory setting More information on each of the different keypad transmission formats is available in the following subsections 5 7 1 Single Key Wiegand 6 Bit Rosslare Format Each key press im...

Page 20: ...11110000 6 10010110 1 11100001 7 10000111 2 11010010 8 01111000 3 11000011 9 01101001 4 10110100 01011010 A in Hexadecimal 5 10100101 01001011 B in Hexadecimal 5 7 4 4 Keys Binary Facility Code Wiegand 26 Bit This option buffers 4 keys and outputs keypad data with a 3 digit Facility code like a standard 26 bit card output The Facility code is set in Programming Menu 4 four and can be in the range ...

Page 21: ...setting for the Facility code is 001 see Section 5 11 The keypad PIN code can be one to five digits in length and can range between 0 and 65 535 When entering a keypad PIN code that is less than 5 digits in length must be pressed to signify the end of PIN code entry For keypad PIN codes that are 5 digits in length on the fifth key press of the 5 digit PIN code the data is sent across the Wiegand D...

Page 22: ...ode and keys are valid the data is sent across the Wiegand Data lines as a BCD message If the entry of the 6 digit keypad PIN code is disrupted and no number key is pressed within 5 seconds the keypad clears the PIN code entry buffer generates a medium length beep and is ready to receive a new 6 digit keypad PIN code EP AAAA BBBB CCCC DDDD EEEE FFFF OP Where A The first key entered D Fourth key en...

Page 23: ...rs the PIN code entry buffer generates a beep and is ready to receive a new keypad PIN code If the entry of the digit keypad PIN code is disrupted and a number key or is not pressed within 5 seconds the keypad clears the PIN code entry buffer generates a medium length beep and is ready to receive a new keypad PIN code 5 8 Selecting the Proximity Card Transmission Format The AY Q6350 has different ...

Page 24: ...IN 3 Wiegand 26 Bit with Facility code output 4 Wiegand 32 Bit 5 Wiegand 32 Bit reverse output 6 Wiegand 34 Bit 7 Wiegand 40 Bit 8 5 9 1 Wiegand 26 Bit In this mode 3 bytes of card serial number are transmitted in Wiegand 26 Bit format Two parity bits are added An even parity bit is sent first followed by three bytes card data than followed by odd parity bit The fourth byte of the cards serial num...

Page 25: ...flash red to indicate that the AY Q6350 is waiting for the PIN code The entered PIN code is buffered up to 5 keys and outputs keypad data with a Facility code much like Option 5 1 to 5 Keys Facility Code 26 Bit Wiegand see Section 5 7 5 5 9 4 Wiegand 26 Bit and Facility Code In this mode a 1 byte Facility code followed by 2 bytes of the card s serial number are transmitted in Wiegand 26 Bit format...

Page 26: ...e transmitted in Wiegand 32 bit format Bytes are sent in reversed order LSB part of card serial number is sent first and MSB byte is sent last No parity bits are added DDDD DDDD BBBB BBBB CCCC CCCC AAAA AAAA Where D 1st LSB byte of card serial number C 2nd byte of card serial number B 3rd byte of card serial number A 4th MSB byte of card serial number 5 9 7 Wiegand 34 Bit In this mode 4 bytes of c...

Page 27: ... in reversed order LSB part of card serial number is sent first Last byte sent is Checksum byte generated by adding 4 data bytes and discarding remainder beyond 8 bytes AAAA AAAA BBBB BBBB CCCC CCCC DDDD DDDD CSUM Where A 4th MSB byte of card serial number B 3rd byte of card serial number C 2nd byte of card serial number D 1st LSB byte of card serial number CSUM Checksum value 1 byte A B C D 5 10 ...

Page 28: ...e 1 Enter Programming mode 2 Press 4 to enter Menu 4 The Transmit LED turns red 3 Enter the new 3 digit code you wish to set as the Facility code You hear three beeps The system returns to Transmit mode The default Facility code is 001 Facility codes can be in the range between 000 and 255 5 12 Setting the Backlight To set the backlight 1 Enter Programming mode 2 Press 6 to enter Menu 6 The Transm...

Page 29: ... careful before using this command Doing so erases the entire memory that includes all user and special codes and returns all codes to their factory default settings To return to factory default settings 1 Enter Programming mode 2 Press 0 to enter Menu 0 The Transmit and Program LEDs flash red 3 Enter your Programming code If the Programming code is valid all memory is erased You hear three beeps ...

Page 30: ...he Programming code is forgotten the AY Q6350 may be reprogrammed in the field using the following instructions 1 Remove power from the reader 2 Activate tamper by removing the reader from the wall or removing the reader s case 3 Apply power to the reader 4 You now have 10 seconds to enter Programming mode using the factory default Programming code 1234 ...

Page 31: ...l 31 A Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www rosslaresecurity com Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them ...

Page 32: ... na rosslaresecurity com Europe Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina Tel 54 11 4001 3104 support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support cn rosslaresecurity com India Rosslare Ele...