98
Drain valve
5222
6
Assembling
1. Connect the pressure hose to the lower part
of the valve. Verify that the hose is not bent or
pinched.
2. Fit the rubber bellows onto the sleeve coup-
ling.
3. Hook the valve onto the bolts and turn the
valve into position. Secure the 4 retaining
bolts of the valve.
4. Secure the hose clamp at the connection of
the rubber bellows on the sleeve coupling.
5. Connect the drain hose to the upper part of
the valve.
6. Turn on the main power to the machine and
verify correct valve operation and that it does
not leak.
7. Reattach the front cover.
5
6
4
7
6
5
2
1
3
5
9
101772
8
1. Upper part
2. Rubber diaphragm with drain connection
3. Pressure plate
4. Recoil spring
5. Cylinder
6. Piston
7. Diaphragm
8. Nipple for connection of feed hose from
control valve
9. Lower part
Summary of Contents for EX618
Page 4: ...Intentionally blank ...
Page 6: ...Intentionally blank ...
Page 12: ......
Page 20: ......
Page 75: ...75 I O modules 6637 22G The gas heating unit must be connected to connections 17 18 and 19 ...
Page 82: ......
Page 94: ......
Page 100: ......
Page 104: ......
Page 106: ......