I/O modules
22B
6316
• To start the machine from a central payment system, the payment system
must transmit a start pulse to the machine. Door lock activates on positive
flank and program starts on negative flank of start pulse. The start pulse can
be either 230V or 24V. In order to receive a feedback signal once the machine
has started, 230V or 24V must be connected to connection 19. The feedback
signal on connection 18 remains active (high) during the entire wash program.
Summary of Contents for EX618
Page 4: ...Intentionally blank ...
Page 6: ...Intentionally blank ...
Page 12: ......
Page 20: ......
Page 75: ...75 I O modules 6637 22G The gas heating unit must be connected to connections 17 18 and 19 ...