66
I/O modules
A
B
1
2
3
4
1
2
3
4
5
7
6
9
12
6598
13
6572
External connections to I/O module type 2
Connection of external dosing equipment
The external dosing equipment power supply
must never be connected to the machine's inco-
ming terminal block.
Machines fitted with connectors
• Connect the pump assembly to connections
A and B on the washing machine. Connect
the signal cable to B and the power supply to
A.
Machines without connectors
• Connect the external pump assembly for
liquid washing detergent to I/O module 2,
which is located to the right of the incoming
power supply.
The I/O module has edge connectors for con-
necting external pumps.
The edge connectors may be removed from
the board when connecting the cabling.
1 = N
2 = L
4 = Earth
11 = N
18 = Program
12 = Signal 1
13 = Signal 2
14 = Signal 3
15 = Signal 4
16 = Signal 5
12