warema_890558_alhb_en_v5•2022-02-01
We reserve the right to carry out improvements
69
8.4.7 Runtime UP mm:ss
The "Runtime UP" of a sun shading product is the time it requires to travel
from the bottom to the top position.
Set the actual run times for each product. This is the only way to ensure that
the product will function as desired when moving to position (xx%).
Experience has shown that the run times of sun shading products differ.
A roller shutter with a length of 150 cm has a much shorter run time than
an articulated arm awning with a 300 cm projection. The Wisotronic allows
these run times to be adjusted to the nearest second for the connected
product. You can also set separate run times for UP and DOWN if a product
requires more time to be raised than to be lowered.
Select the [
Runtime UP mm:ss
] line by turning the touch wheel; press the
touch wheel.
The minutes are shown enlarged. Set the minutes by turning the touch wheel;
press the touch wheel. The seconds are shown enlarged; set the seconds in
the same manner and press the touch wheel.
8.4.8 Runtime DOWN mm:ss/On
period mm:ss
Set the "Runtime DOWN" in the same manner. Or:
Set the on-time for single-pole products such as lights. The product is
switched off automatically after this duration.
Exception: In the "Permanent command" manual operating mode, the product
remains switched on until operated again.
8.4.9 Slat products
The slat angle can be adjusted at outside venetian blinds and internal vene-
tian blinds in order to change or optimise the light incidence in a room.
The following diagram explains the slat angle settings:
Positive value:
Slats are tilted outward
Negative value:
Slats are tilted inward
Setting 0°:
Slats remain in the horizontal position
+80
0
-80
Outside
Inside
Slat angle for external and internal venetian blinds
Products