warema_890558_alhb_en_v5•2022-02-01
We reserve the right to carry out improvements
100
Wisotronic 1-channel
Installation instructions
Technical data
13 Technical data
Wisotronic 1-channel
Min.
Typ.
Max.
Unit
Supply
Operating voltage
85
230
265
V AC
Frequency
50
60
Hz
Power consumption
< 1
5
W
Floating output
Switching capacity per channel
at 230 V AC/cos ϕ 0.6
500
VA
Switching capacity per channel
at 24 V DC
72
W
Fuse protection per channel
3.15
AT
Internal temperature sensor
Measuring range
0
50
°C
Miscellaneous
Display
Graphic display, 240 x 320 pixels
Program user guidance
Menu-guided text display
Program entry
4 capacitive buttons/touch wheel
HF receiver
Receiving frequency ASK
(OOK)
433.92
MHz
Range
(environment without interfer-
ence)
30
m
Enclosure
Dimensions H×W×D
177 × 97 × 5
Degree of protection
IP40
Safety class
II
This device complies with the EMC directives for use in residential and commercial
areas.
Connection
Control panel
Plug-and-socket connection
Power unit
Spring terminals
Miscellaneous
Display
Graphic display, 240 x 320 pixels
Program user guidance
Menu-guided text display
Program entry
4 capacitive buttons/touch wheel
Conformity
Available at http://
Ambient conditions
Operating temperature
0
20
40
°C
Storage temperature
0
20
50
°C
Rel. humidity
(non-condensing)
10
40
85
%RH
Degree of soiling
2
Article number
Wisotronic 1-Kanal white
1002 733
Wisotronic 1-Kanal black
1002 734