5.3.2 Sun shading drive
If you wish to activate several sun shading products with the Wisotronic, you
can connect a floor distribution control or motor control units to terminals X2
instead of a sun shading drive.
NYM-J 3x1,5
Supply line
100-240 V AC
50/60 Hz / 16 A
3,
15
AT
1
1
3
3
2
2 Plug-and-socket connection
2
3
1
GNYE
BU
BN
BK
M1~
Motor 1
H05RR-F 4 G 0.75 BK
Only one drive may be
connected per channel.
Parallel connection of
multiple drives will
damage the motor.
L
N
PE
Terminal
(included)
Fig. 13
Connection of a sun shading drive
Terminal blocks X1, X2
Permissible line cross section
0.2 to 1.5 mm
2
single-wire
Stripping length
10 mm
WARNING
In a permanently routed installation, there must be an in-series
disconnecting and isolating device to separate the Wisotronic from
the supply voltage (switch according to EN 60335-1, Section 25.2, e.g.
circuit breaker). The associated motor control unit (MSE) and its power
consumers should not be protected by this circuit breaker.
Connection