warema_890558_alhb_en_v5•2022-02-01
We reserve the right to carry out improvements
70
Wisotronic 1-channel
Installation instructions
A motor requires a certain time to turn the slats from the position "+80°" to
the position "-80°" (as in our simple example). In addition, this
tilting time
differs for various product types. For example, an internal venetian blind re-
quires approximately 0.5 seconds, whereas this procedure can also take 1.6
seconds for an outside venetian blind, type WAREMA E80A6. If this tilting
time is known, it needs to be saved in the Wisotronic together with the maxi-
mum and the minimum possible tilt angle. Subsequently, the tilt angle can be
specified by simply entering the angles. The time-consuming manual determi-
nation of tilting times becomes obsolete.
Parameters have been predefined for standard WAREMA products. An over-
view is presented in
Chapter 10.3 on page 91
. This list may expand as
the product is updated.
If you wish to control third-party products, ask for information from the re-
spective manufacturer.
Minor changes may be necessary depending on the package weight and
motor type.
Minimum slat angle
First set the minimum slat angle according to the above table:
Select the [
Minimum slat angle
] line by turning the touch wheel; press the
touch wheel.
Change the value by turning the touch wheel.
Accept the value by pressing the touch wheel.
Maximum slat angle
Set the maximum slat angle in the same manner.
Tilting time
Then set the tilting time for the slat according to the above table or manufac-
turer specifications.
Number of tilting steps
This menu line allows you to set how many tilt steps the slats perform be-
tween the two extreme angles in case of manual operation; the preset factory
value is 6 for internal and external venetian blinds.
Products