40ea manual
- 5 -
be connected to other fireplaces or equipment. Installation kit 4880 is required for the installation. In the example in the
picture, the fuel is fed from the fuel tank 4130 (130 l) under the floor.
Things to note when selecting the installation location
When selecting the installation location and method, note the following:
- If you choose the wall lead-though method, install the device on a wall where the wind pressure does not directly
impinge the flue-gas exhaust head. When the device is running on low power, wind pressure can snuff out the burner
flame. The burner will also generate more scale due to changes in wind pres¬sure.
- The length of the control panel wire is 3 m. Do not install the device near to an external door or a window, because the
temperature changes in these loca¬tions are too great. The control panel contains a thermostat sensor.
- Flue installation will slightly increase the generation of burner scale.
- Avoid making the fuel and electrical lines that lead to the device excessively long.
- The device must be positioned so that it is protected from water drips, spills or splashes.
When installing the device, bear in mind that may be necessary to detach the device for maintenance. Therefore, it is
advisable to make the connections easy to open and disconnect. The device does not need to be detached to clean the
burner.
The heater should be installed on the level. The inclination must not exceed 5°. While the device should not breakdown,
if it is temporarily tilted at a steep angle (even for some hours), the burner will not yield the optimal performance, if it is
continuously inclined.
Also, consider where you place the control panel, as the length of the control panel?s cable may pose some limitations.
Avoid installing the control panel in the immediate vicinity of a water outlet.
If possible, install the control panel on a vertical surface.
We recommend that the device be installed by an authorised Wallas service shop.
Protection of pipes, hoses and cables
Power cables, fuel- and water hoses must be protected in locations where they are susceptible to mechanical damage
due to sharp edges or heat.
Water connections
Warning
Make sure that parts which where water is involved are installed and placed so that they do not create any burn for skin
for human or animal, or it should not harm any heat sensitive material around.
Before doing any installation or service work for the heater or water system, shut off the heater and let the system cool
down to prevent any burn skin.
Note!
- Make sure that the flow direction is correct in your installation.
- Route all the water hoses so that they are rising from the lowest point to higher. This will prevent air locks from the
system.
Summary of Contents for 40ea
Page 4: ...40ea manual 3 Conformity with ecodirective Wallas 40EA conforms with ecodirective...
Page 11: ...40ea manual 10 Electrical connections of the device...
Page 12: ...40ea manual 11...
Page 13: ...40ea manual 12...
Page 19: ...40ea manual 18 Turn the heater of by sending 1234 R10...
Page 27: ...40ea manual 26 Wall lead through section view...
Page 30: ...40ea manual 29 Measurements for the hole are 516x328mm...
Page 39: ...40ea manual 38 5 Unplug the drill pump s hose and plug T branch...