Error
Repeated sequence: blink N times (0.5 s on, 0.5 s off), 5.0 s off.
1 blink - Glow plug
Glow plug open circuit
Glow plug short circuit
2 blinks - Burn fan
Missing tachometer feedback
3 blinks - Burner temperature sensor
Burner temp. sensor: Invalid reading
4 blinks - Other temperature sensor
Air temp. sensor: invalid reading / missing
Water temp. sensor: invalid reading / missing
Room temp. sensor: invalid reading / missing
5 blinks - Ventilation fan
Missing tachometer feedback
6 blinks - Overheat
Any overheat
7 blinks - Fuel
No ignition during startup
Unexpected flame-out
With fuel-in-air detection: no fuel detected
Fuel pump fault
8 blinks - Water pump
Water pump open circuit
9 blinks - General
Any other error