Heater operation
Wallas heater 40 EA is designed especially for water circulation heating systems outside of the electricity network.
Light furnace oil, diesel oil or paraffin can be used to fuel the device. The heater is fed with fuel from a separate tank,
which is positioned below the heater. The heater is powered by a 12-volt battery, which can be recharged, for example,
by a solar cell, wind generator or a mains power adapter.
The combustion air is fed in from outside the device and its circulation is completely enclosed, and balanced with the
flue-gas exhaust head, which eliminates the effect of wind pressure on the combustion.
The heater's evaporation burner is activated automatically when the device is started. The glow plug in the burner
ignites the fuel that has been pumped into the burner. The glow time is fixed: it starts and ends automatically.
The heat sensor, in the heater, detects the flame's heat and lights the red LED to signal that the device has started.
All functions are controlled electronically. The fuel pump and combustion air blower are fully stabilised against voltage
fluctuations, which ensures clean combustion, regardless of changes in the battery voltage.
The heater is equipped with built-in overheat protection, which cuts the fuel feed if the device overheats.
When the heater is switched off, it cools down automatically. The cooling function ventilates the burner, and discharges
the flue-gases generated during the switch-off, to the outside of the cottage.
Things to note during installation
Basic installation methods
The most common installation method is a wall lead-through. Installation kit 4880 and a flue-gas exhaust head 4004
have been used in the installation. In addition, the fuel tank 4030 (30 l) has been installed in the base housing 4031.
Flue installation. This installation method requires the building?s chimney to have one flue available. The flue must not
Summary of Contents for 40ea
Page 4: ...40ea manual 3 Conformity with ecodirective Wallas 40EA conforms with ecodirective...
Page 11: ...40ea manual 10 Electrical connections of the device...
Page 12: ...40ea manual 11...
Page 13: ...40ea manual 12...
Page 19: ...40ea manual 18 Turn the heater of by sending 1234 R10...
Page 27: ...40ea manual 26 Wall lead through section view...
Page 30: ...40ea manual 29 Measurements for the hole are 516x328mm...
Page 39: ...40ea manual 38 5 Unplug the drill pump s hose and plug T branch...