40ea manual
- 25 -
Accessories 4004 and 4880 are required for the installation.
Note that different measurements for insulation are given for Finland, as opposed to Sweden and Norway, due to
different national regulations.
10. Drill or cut an opening in the wall for the exhaust pipe and its insulation (ø 120 mm, Finland/ ø 320 mm, Sweden
and Norway). And the combustion air intake pipe (ø 50 mm). The cover plate (16) can be used as a stencil.
11. Cut both pipes (18 and 21), so that the pipes extend from the wall ca. 40 - 45 mm (23 and 24) when the pipes have
been pushed all the way in the heater connection pipes (25 and 26) and the heater is positioned at least 70 mm
(Finland) / 100 mm (Sweden and Norway) from the wall.
12. Install the cover plates (16 ja 17) on the lead-through openings and seal the connection between the wall and the
plate with silicone paste.
13. Push the pipes (18 and 21) all the way into the connection pipes (25 and 26) and seal the exhaust pipe's connection
(25) with a pipe clamp (11) and the combustion air pipe's connection (26) with a hose binder (10). (Both ties can be
found in the heater accessory bag.) The exhaust pipe cannot be tightened sufficiently by any other fastening than a
pipe clamp (11), which must be tightened sufficiently to lock the pipe in place.
14. Place mineral wool (19) on the exhaust pipe (18) so that the insulating material extends from the back surface of
the heater to ca. 10 mm outside the wall (27). Place the insulation mantel plate (20) on the insulation.
15. Then, push the heater to a distance of 70 / 100 mm from the wall, while guiding the hoses and the insulation
through the lead-through openings.
16. Adjust the length of the insulation mantel plate (20), by cutting it so that its end protrudes from the wall ca. 10 mm,
and cut the edge of the sheet metal into 10-20 mm strips (28), as shown in picture 1. Fold the strips carefully on to the
surface of the sheet metal cover.
17. Seal the clearance between the sheet metal cover (17) and the flue-gas exhaust head (15) with silicone paste and
push the head into place in the wall. Attach the head to the wall with screws (30, 4 items 4,5x25). The lid of the flue-gas
exhaust head (15) must be opened before installation - screw (31). Ensure that the ends of the hoses (23 and 24)
extend to the limiters (32 and 33).
18. Finally, fasten the heater to the floor or the base housing (12).
Summary of Contents for 40ea
Page 4: ...40ea manual 3 Conformity with ecodirective Wallas 40EA conforms with ecodirective...
Page 11: ...40ea manual 10 Electrical connections of the device...
Page 12: ...40ea manual 11...
Page 13: ...40ea manual 12...
Page 19: ...40ea manual 18 Turn the heater of by sending 1234 R10...
Page 27: ...40ea manual 26 Wall lead through section view...
Page 30: ...40ea manual 29 Measurements for the hole are 516x328mm...
Page 39: ...40ea manual 38 5 Unplug the drill pump s hose and plug T branch...