![Waitzinger THP 94/42 R 4 XXT User Manual Download Page 89](http://html1.mh-extra.com/html/waitzinger/thp-94-42-r-4-xxt/thp-94-42-r-4-xxt_user-manual_3154061089.webp)
S
TARTING
UP
AND
OPERATING
C
HAPTER
7
THP 94/42 R 4 XXT
THP 125/42 R 4 XXT
THP 140 H/42 R 4 XXT
GB-07.2005
7-19
7.5.4.2
Pump control at the hydraulic control block
When controlling the valves manually, never run the engine at full speed.
WARNING:
Valves and solenoids can be up to 100
°
C temperature, risk of burns!
•
Moving the drive cylinder
Actuate Y4 a or b using a screwdriver (4 mm) or similar tool. Then press Y3 manually and move the drive
cylinder to the desired position. Simultaneously releasing Y3 and Y4 will bring the cylinder to a halt.
•
Moving the oscillation cylinder
Actuate Y5 a or b using a screwdriver (4 mm) or similar tool. Then press Y3 manually and move the drive
cylinder to the desired position. Simultaneously releasing Y3 and Y4 will bring the cylinder to a halt.
WARNUNG
3
4
2
1
7
5
6
1
Valve Y5b
2
Push button
5
Valve Y5a
6
Valve Y4a
3
Valve Y3
4
Pressure sensor
7
Valve Y4b
Fig. 7.23 Pump hydraulic control block