THP 94/42 R 4 XXT
THP 125/42 R 4 XXT
THP 140 H/42 R 4 XXT
GB-07.2005
S
AFETY
INSTRUCTIONS
AND
INFORMATION
C
HAPTER
2
2-17
WARNING:
Before performing any electric arc welding, always unplug the cables from
the control cabinet and disconnect the battery.
To disconnect the battery, undo the positive and negative terminal
connections or switch off the Nato switch at the battery if this is fitted.
墌
Disconnect machines with electrical equipment such as radio remote control (receiver), controls etc. before
performing electric arc welding.
墌
Modifications, welding and repair work on the distributor boom and all assemblies associated with it, load-
bearing elements, securing points, outriggers, on the mounting frame and any part of the pump or pressure-
bearing components may only be performed by persons appointed by the manufacturer. Special care must be
taken in respect of boom mountings and outriggers used as hydraulic or diesel tanks.
墌
When replacing electrical, pneumatic or hydraulic components (valves, pumps etc.), the required data (pressure,
voltage etc.) should be checked from the machine data sheet, test sheet or circuit diagram and adjusted as
necessary.
墌
Maintenance and repair work may be carried out only after fluids have been depressurised. No changes of any
sort to the hydraulics are permissible. We emphatically warn against improper repairs to hydraulics. Test
certificates supplied with hydraulic components should be carefully filed away for reference.
墌
If any component is removed, carefully note how it was fitted and replace it correctly referring to the spare
parts data sheet / service information.
2.12
High-tension overhead electric cables
WARNING
Fig. 2.13 Safety distances to high-tension overhead electric cables