62
VERSION 01/2020
ORDER NUMBER DOC2397091
SprayPackE
No.
Signal
Application
1+2 Floating contact input
External emergency stop buttons or fire
extinguishing system. Channel 1
If using bridge, remove!
3+4 Floating contact input
External emergency stop buttons or fire
extinguishing system. Channel 2
If using bridge, remove!
5+6 Floating contact input
Booth exhaust air OK signal
If using bridge, remove!
7
24 VDC digital input 10 mA
Conveyor running signal
8
24 VDC digital input 10 mA
Powder center ready signal
If using bridge, remove!
9
24 VDC digital output
Guns ON
Spray at least one or more guns.
10+11 Floating contact output
System OK signal
12+13 Floating contact output
Emergency stop button, relay channel 1
14+15 Floating contact output
Emergency stop button, relay channel 2
16
+24 VDC operating voltage
For inputs, maximum 100 mA loading
Earth/ground potential
For earth connection or ground potential for
24 V operating voltage