55
VERSION 01/2020
ORDER NUMBER DOC2397091
SprayPackE
Level 1
Level 2
Description
IO logic
Positive PNP
Negative NPN
IO pin2
IO function
Trigger input
Teach input
Area output
Warning output
IO pin5
Inversion
Normal
Inverted
IO pin6
Teach in height Run
Exit
IO pin7
Area logic
AND
OR
Start beam
Enter value
min = 1
0001
max = 1774
End beam
Enter value
min = 1
0024
max = 1774
6.10.3.2 INDIVIDUAL-SEGMENT MEASURING OPERATION
The MCE control software anticipates a signal at input 1 if one or more light beams are
interrupted. Only output 1 (IO pin2) needs to be configured for this.