23
VERSION 01/2020
ORDER NUMBER DOC2397091
SprayPackE
5.4
CPE CONNECTIONS ON REAR SIDE
1
2
3
8
7
6
5
4
P_03725
9
Signal
Description
1 Supply for movement devices
Cable gland can be split for standard cable for
movement devices
2 230 VAC for MCE
Power supply for MCE (output)
3 Power supply for input
Current input for entire SpraypackE system
3P+N+PE 230/400 V 50/60 Hz
4 Cover
Not used with CPE type
5 Emergency stop output
Cable gland for cable for relaying emergency stop
6 Cover
Not used with CPE type
7 MCE interlocking
Connection with MCE, safety interlock
8 230 VAC for EPG S2
Power supply for EPG S2, group 1
9 230 VAC for EPG S2
Power supply for EPG S2, group 2
Summary of Contents for SprayPackE