6.10.3.3 MULTI-SEGMENT MEASURING OPERATION
With the CSL710, the total scan length can be split into 4 segments. These are communicated
to the control unit as 4 digital signals. These 4 segments may be selected to be equal, unequal
or overlapping.
To activate this function, the number of beams for correct input must be known
(see Chapter
).
Example of a CSL710 1590/20 light curtain with 80 beams with division into
4 non-overlapping segments of the same height.
1
80
P_03736
1
20
21
40
41
60
61
80
Output 4, IO pin7
Output 3, IO pin6
Output 2, IO pin5
Output 1, IO pin2
Note:
For the multi-segment measuring operation, the corresponding configuration must be entered
for each output (1–4). See "Individual-segment measuring operation" description.
Output 1 = IO pin2, positive PNP, area output, normal, OR; start beam 1, end beam 20
Output 2 = IO pin5, positive PNP, area output, normal, OR; start beam 21, end beam 40
Output 3 = IO pin6, positive PNP, area output, normal, OR; start beam 41, end beam 60
Output 4 = IO pin7, positive PNP, area output, normal, OR; start beam 61, end beam 80