6.12.1 GROUNDING OF CONTROL UNITS IN RACK
P_01506
The control units are grounded with the grounding cables supplied. The grounding cable is
secured to the control unit's grounding connection and the rack with the screws provided.
1 Only use mains cables with grounding strand!
2 Connect grounding cable with booth and signal ground!
3 Connect grounding cable to an uncoated metal part of the booth!
4 Remove all paint from hooks and other hanger parts!
5 Do not wear insulating gloves!
6 Wear electrostatically conductive footwear!
7 The floor must be electrostatically conductive!
8 Connect floor and booth with system ground!
6.13 SAFETY CHECKS
A skilled person must check to ensure that the device is in a reliable state after it is assembled
and commissioned.
This includes:
– Carry out safety checks in accordance with Chapter
.