SprayPackE
6.14 INTERLOCKING
NOTICE
Danger of damage to the device!
Interlock connecting plug: Pins 1 to 11 and pin 16 only carry 24 V DC control voltage
and are supplied by the MCE. Applying an external voltage to these pins will destroy
the MCE.
Pins 10+11, 12+13 and 14+15 are used to control external functions.
Maximum permissible contact load 230 V/1 A.
If the bridged inputs are used, the bridges must be removed.
Pin assignment of plug:
P_03732