38
Finish 270 / 250
GB
descrIptIon of unIt
3.6
tecHnIcAl dAtA FInISH 250
Voltage :
230 V AC, 50 Hz
Fuses :
16 A time-lag
Unit connecting line :
4 m long, 3 x 1.5 mm²
Max. current consumption
hose heating :
4,6 A
Degree of protection :
IP 54
Acceptance capacity :
1,1 kW
Max. operating pressure :
25 MPa (250 bar)
Max. volume flow :
2.2 l/min
Volume flow at 12 MPa
(120 bar) with water :
1.8 l/min
Max. temperature of the
coating material :
43 °C
Max. viscosity :
15,000 mPas
Empty weight pump :
28 kg
Hydraulic oil filling
quantity :
0.65 liter
Max. vibration at the spraygun
:
lower than 2.5 m/s²
Max. sound pressure level:
74 dB (A)*
*Place of measurement: 1 m distance from unit and 1.60
m above floor, 12 Mpa (120 bar) operating pressure,
reverberant floor
Voltage :
230 V AC, 50 Hz
Fuses :
16 A time-lag
Unit connecting line :
4 m long, 3 x 1.5 mm²
Max. current consumption
hose heating :
6.0 A
Degree of protection :
IP 54
Acceptance capacity :
1.3 kW
Max. operating pressure :
25 MPa (250 bar)
Max. volume flow :
2.9 l/min
Volume flow at 12 MPa
(120 bar) with water :
2.3 l/min
Max. temperature of the
coating material :
43 °C
Max. viscosity :
15,000 mPas
Empty weight pump :
29.5 kg
Hydraulic oil filling
quantity :
0.65 liter
Max. vibration at the spraygun
:
lower than 2.5 m/s²
Max. sound pressure level:
74 dB (A)*
*Place of measurement: 1 m distance from unit and 1.60
m above floor, 12 Mpa (120 bar) operating pressure,
reverberant floor
3.7
tecHnIcAl dAtA FInISH 270
Before start with the backfitting, pull of main
plug of socket, disassemble suction system
and high pressure hose
1
Summary of Contents for Finish 250
Page 19: ...19 Finish 270 250 10 9 Schaltplan d reparaturen am ger t...
Page 24: ...24 Finish 270 250 ersatzteile und zubeh r Ersatzteilbild Pumpenaggregat d...
Page 48: ...48 Finish 270 250 GB Repairs at the unit 10 9 Connection diagram...
Page 53: ...53 Finish 270 250 GB Spare parts diagram pump aggregate Spare parts and accessories...
Page 77: ...77 Finish 270 250 10 9 Sch ma lectrique F R parations sur l appareil...
Page 107: ...107 Finish 270 250 10 9 Elektrisch schema Reparaties aan het apparaat NL...
Page 112: ...112 Finish 270 250 Onderdelenafbeelding pompaggregaat NL Accessoires en onderdelen...
Page 118: ...118 Finish 270 250 NL CE Verklaring van overeenstemming...
Page 119: ...119 Finish 270 250 NL CE Verklaring van overeenstemming...