8.2.4
CHANGING THE SPRAY GUN WITH HOSE SET
Disassembly
1. Dismount the VM 5020W control unit as described in Chapter 10.5.
2. Rear of the control unit: Loosen the knurled nut on the gun cable (5)
and remove plug.
3. Loosen the union nut (4) of the air hose at the AquaCoat cabinet.
4. Loosen the union nut (6) on the bared part of the product hose (7).
5. Unscrew knurled nut (2).
6. Carefully remove the gun (1) together with the hose set.
Assembly
The GM 5020EACW spray gun can be combined with diff erent hose sets. The available hose
sets are listed in the accessories (Chapter 13.3).
1.
Push bared part of product hose approx. 1.25 m; 4.1 ft through the opening as far as
the mounting plate.
2.
Fasten mounting plate (3) to grounding screw with knurled nut (2).
3.
Screw on stripped end of product hose (7) with union nut (6):
-
Puma / EvoMotion: To product fi lter.
-
Cobra: To potential equalization point of the grounding switch.
4.
Screw air hose (4) to the AquaCoat cabinet.
5.
Remove protective sleeve (10), insert gun cable (5) through the bushing (8), place
protective sleeve (10) again. Connect gun cable (5) to control unit (gun connection (9)).
Secure with knurled nut. Push protective sleeve (10) over the knurled nut and gently
fasten using screw (11). Attach strain relief grommet (8).
6.
Fasten the hose set using hose holder (12).
7.
Carefully push the VM 5020W control unit back again to the limit stop. Pay attention
to connecting lines and connecting cables at the back of the control unit!
8.
Screw the VM 5020W control unit on the cabinet.