OPERATING MANUAL
EDITION 02/2016
ORDER NUMBER DOC 2366600
7.3.14
SETTING THE CURRENT LIMITATION
Procedure:
1.
Press the "Current Limitation" button (5) to
adjust the limitation of the spray current.
The LED (6) indicates that current limitation
is selected.
2. The current limitation can now be
adjusted using the universal rotary
controller (2) between 10 - 100 μA with
a resolution of 1 μA. The corresponding
value is indicated in the LED display (27).
Above the "Current Limitation" button (5) is the "Current Limitation" bar graph display (22).
If the control unit is in the ready position, this light strip shows the set value as a dot.
The current limitation is an adjustable threshold. If this threshold is exceeded, for example,
by the spray gun having approached the object being sprayed, the high voltage is adjusted
downwards until the threshold is no longer exceeded.
The set values for high voltage (40 kV) and for spray current limitation (83 mA) that are
shown in the examples are saved in R2 by pressing and holding for a longer time the recipe
push button (for > 2 seconds).