73
B_04789
9
10
Y
11
1
12
OPERATING MANUAL
EDITION 02/2016
ORDER NUMBER DOC 2366600
7.3.8
REPLACING THE AIRCOAT FLAT JET NOZZLES
1.
Switch off control unit.
2.
Relieve pressure Chapter 7.3.4.
3.
Secure the spray gun (1) using the trigger lock (14).
4.
Unscrew union nut completely (12) and remove air cap (10).
5.
Remove and clean the ACF5000 AirCoat nozzle (11).
6.
Insert new ACF5000 nozzle (11) into the valve housing.
7.
Put the air cap (10) on the nozzle (11) and pay attention to the position of the guide
surfaces.
8.
Screw union nut with attached nozzle guard (9) to the gun body and make sure that
the air cap horns lie in the designated recess (Y).
9.
Before tightening with the air cap horns (Y), set the desired jet level and then tighten
the union nut to stop by hand.
The AirCoat ACF5000 nozzles (11), the nozzle inserts (3) and the nozzle screw connection (7)
can be placed in a cleaning solvent recommended by the lacquer manufacturer.
All other nozzle parts may not be put into cleaning solvent. Clean these parts with a
cleaning solvent recommended by the lacquer manufacturer and dry with a cloth or
blow gun.
7.3.9
CLEANING OF THE NOZZLE PARTS
Defective AirCoat nozzle!
Insuffi
cient paint application quality.
Do not use sharp-edged objects to treat carbide on the AirCoat nozzle.
NOTICE