Technical description
SinePower
40
The output voltage corresponds to the household voltage from the socket
(pure sine wave).
The inverter has a 230 V
AC
priority circuit. If an external 230 V
AC
voltage is
connected, this will have priority. If no external 230 V
AC
voltage is connected,
then the connected battery will be used as the power supply.
Please observe the values for constant output power and peak output power
as indicated in chapter “Technical data” on page 53. Never connect devices
that have a higher power requirement.
I
Note
Note when connecting devices with an electrical drive (such as
power drills and refrigerators), that they often require more power
than is indicated on the type plate.
The inverter has various protective mechanisms.
z
High voltage shutdown:
The inverter shuts itself off when the voltage
exceeds the cut-off value. It restarts when the voltage returns to the re-
start value.
z
Low voltage shutdown:
The inverter shuts itself off when the voltage
sinks below the cut-off value. It restarts when the voltage rises to the re-
start value.
z
High temperature shutdown:
The inverter switches off when the temper-
ature inside the device or the temperature on the cooling element exceeds
a cut-off value. It restarts when the voltage rises to the restart value.
I
Note
The individual values are found in chapter “Technical data” on
page 53.
The inverter can be switched into an energy saving mode (Standby) , so that
the battery connected to the inverter does not discharge too quickly.
The inverter can be connected to an exhaust system with the included ex-
haust adapter. This allows the warm exhaust to be diverted outside.
The connection cable can be attached to the back of the device via the cable
socket.
The inverter can be turned on and off with an external switch (not included in
package).
The manufacturer offers a remote control as an accessory for the inverter.
_MSP702_MSP2524.book Seite 40 Montag, 23. Mai 2011 4:53 16