Cleaning and caring for the inverter
SinePower
52
12
Cleaning and caring for the inverter
a
Caution
Do not use sharp or hard objects or cleaning agents for cleaning as
these may damage the device.
➤
Occasionally clean the device with a damp cloth.
13
Troubleshooting
I
Note
If you have detailed questions on the
specifications
of the
inverter
please contact the manufacturer.
e
Warning!
Do not open the device. You risk sustaining an electric shock by do-
ing this.
No output voltage
The “Power Status” LED (fig.
2
2, page 4) displays the fault in red:
LED display
Cause
Remedy
Quick flashing
Input voltage too high The inverter is only intended for the voltage indi-
cated.
Slow flashing
Input voltage too low
The battery needs charging.
Check the cables and connections.
Occasional flash-
ing
Overheating
Switch off the inverter and the appliance.
Wait 5 to 10 minutes and switch the inverter on
again without any appliances.
Reduce the load and make sure the inverter has
better ventilation. Then switch the appliance back
on.
Constantly lit
Short circuit or
reversed polarity
Excessive load
Switch off the inverter and remove the appliance.
Then switch the inverter back on without the appli-
ance. If no excessive load is now shown, then
there is a short circuit in the appliance or the total
load was higher than the power specified on the
data sheet.
Check the cables and connections.
_MSP702_MSP2524.book Seite 52 Montag, 23. Mai 2011 4:53 16