Connecting the inverter
SinePower
48
10.4
Connect the 230V output cables
e
Caution – danger of electrocution!
Before connecting the 230V
AC
output cable make sure the inverter
is switched off at the main switch.
➤
Connect the 230 V
AC
connection cable with safety coupling (fig.
1
4,
page 3) to the 230V
AC
output jack (fig.
3
4, page 4).
10.5
Connect multiple appliances
The device is equipped at delivery with galvanic isolation. For the safe oper-
ation of multiple appliances, it is essential that a circuit breaker (residual cur-
rent circuit breaker) is built into the socket distribution circuit, see sample
circuit diagram in fig.
0
, page 8.
Sample circuit diagram legend:
e
Caution – danger of electrocution!
If you wish to connect more than one appliance to the inverter and
install a socket distribution circuit, you must arrange a circuit break-
er (residual current circuit breaker) and set a grounding bridge in
the inverter.
➤
Install a residual current circuit breaker in the socket distribution circuit.
No. in
fig.
0
,
page 8
Explanation
1
230 V
AC
power source
2
additional devices, e.g. battery charger, refrigerator
3
DC power source (battery)
4
Inverter
5
Set grounding bridge (At delivery: not set, shown by dotted line)
6
Circuit breaker (residual current circuit breaker)
7
Socket distribution circuit for appliances
_MSP702_MSP2524.book Seite 48 Montag, 23. Mai 2011 4:53 16