English
Problem
Possible cause
Suggested remedy
The display shows
Not enough vacu-
um! Carry on?
Message that appears during the vac-
uum process if the pressure in the air
conditioning system after 8 min is still
more than 50 mbar.
Check the air conditioning system or
the connections between it and the A/C
service unit for leaks.
The display shows
A/C system leak-
age! Carry on?
Message at the end of the vacuum
process. The air conditioning system
shows a vacuum loss of more than
120 mbar during the checking time.
Check the air conditioning system or
the connections between it and the A/C
service unit for leaks.
The display shows
Warning! Not
enough vacuum for injection!
Message that appears during the filling
phase if the vacuum in the air condi-
tioning system is insufficient to end the
process.
Check the air conditioning system or
the connections between it and the A/C
service unit for leaks.
The display shows
Quantity too
large. Fill internal vessel!
Message that appears during the
process input if there is not enough
refrigerant in the internal container to
complete the process.
Fill the refrigerant container.
The display shows
Not enough UV.
Add!
This message appears during the fill-
ing process if there is not enough UV
additive in the container to finish the
process.
Fill the UV additive container.
The display shows
Not enough oil.
Add!
Message that appears during the filling
process if there is not enough fresh oil
in the container to finish the process.
Top up the fresh oil container with a
suitable oil type.
The display shows
Max. filling
time exceeded! Carry on?
Message that appears during the filling
process if the set amount of refrigerant
cannot be filled.
Check that A/C service unit's connec-
tions are not blocked.
The display shows
External tank
empty or closed valve. Check!
Message that appears at the start or
during the filling of the internal refriger-
ant container if the set refrigerant quan-
tity cannot be attained.
Check if the external refrigerant con-
tainer still contains enough refrigerant
or if the valves of the external refriger-
ant container are open.
The display shows
Change the
equipment drier filter! Go on?
This message appears when you
switch on the A/C service unit.
Change the internal filter as soon as
page 23). To skip this, press
ENTER
for 3 seconds.
The display shows
Change the vacu-
um pump oil! Go on?
This message appears when you
switch on the A/C service unit.
Change the vacuum pump oil as soon
on page 25). To skip this,
press
ENTER
for 3 seconds.
The display shows
Printer not in
line! Carry on?
Message indicates a printer fault.
Check if there is paper in the
printer.
Check if the printer is switched
on (yellow LED must be lit con-
stantly).
Check that the cover is closed
properly.
The display shows
Error 01
Refrigerant was added before draining
was completed.
Repeat the draining procedure; do not
interrupt it this time.
The display shows
Error 02
The air conditioning system is leaking.
There is still refrigerant in the air condi-
tioning system.
Fix the leak.
The display shows
Error 52
No USB flash drive was found/recog-
nised.
Insert the USB flash drive.
Ensure that the USB flash flash
drive has been formatted with the
FAT32 file system.
29
Summary of Contents for AirCon ASC 6100G
Page 33: ...English 17 1 Flowchart ASC6100 G Legend 31...
Page 36: ...English 17 2 Circuit diagram ASC6100 G 34...
Page 37: ...English 35...
Page 70: ...French 17 1 Organigramme ASC6100 G L gende 68...
Page 73: ...French 17 2 Sch ma lectrique ASC6100 G 71...
Page 74: ...French 72...
Page 107: ...German 17 1 Flussdiagramm ASC6100 G Legende 105...
Page 110: ...German 17 2 Schaltplan ASC6100 G 108...
Page 111: ...German 109...
Page 113: ...4 4 Tel 49 0 2572 879 0 5 6 Domestic 111...
Page 114: ...Russian 6 1 112...
Page 115: ...Russian 6 2 R1234yf 405 C R134a 743 C R153A 6 3 113...
Page 117: ...10 Dometic 10 10 1 230 V 50 Hz 10 2 10 3 10 4 115...
Page 118: ...11 11 1 2 3 4 5 6 7 USB 116...
Page 119: ...Russian 8 9 10 11 12 117...
Page 124: ...Russian 12 8 8 9 10 12 9 12 2000 g 1 STOP 2 R R1234yf L liquid 122...
Page 137: ...Russian 10 ENTER 11 12 ENTER 13 14 15 D 16 E 17 15 Nm 18 19 20 R1234yf 133 21 133 14 4 135...
Page 139: ...Russian 2 D E 3 I 4 G 5 J 6 J 7 H G 8 9 10 133 14 6 1 2 7783 3 137...
Page 142: ...15 15 ENTER 8 min 50 mbar 120 mbar 134 ENTER 3 136 140...
Page 145: ...Russian 17 1 ASC6100 G 143...
Page 147: ...Russian V1 V2 V3 NCG V4 VC XP XP X3 UV 145...
Page 148: ...Russian 17 2 ASC6100 G 146...
Page 149: ...Russian 147...
Page 183: ...Spanish 17 1 Diagrama de flujo ASC6100 G Leyenda 181...
Page 186: ...Spanish 17 2 Esquema de conexiones ASC6100 G 184...
Page 187: ...Spanish 185...
Page 188: ...4445103553 2022 05 10...