14.4 Calibrating the pressure transducer
The pressure transducer has to be correctly calibrated in order to make accurate pressure measurements. Cali-
bration is required:
•
Every four weeks
•
If the A/C service unit has been subjected to heavy shaking
•
Every time the vacuum pump oil is changed
•
If the display shows implausible pressure readings
1.
In the basic menu use the cursor keys or to select
Other selections
.
Short selection
Free selection
Other selections
ENTER-OK
2.
Depressurise the A/C service unit (as described in chapter
on page 23.
3.
Press
ENTER
to confirm.
4.
Use the cursor keys or to select
Service
Service.
----
5.
Press
ENTER
to confirm.
6.
Enter the password
2224
.
7.
Confirm
Pressure transducer
by pressing
ENTER
.
The device evacuates the service hoses.
8.
Unscrew the service couplings from the service hoses (7) and (8).
9.
Press
ENTER
to confirm.
The device equalizes with the ambient pressure.
10.
Screw the service couplings and hand-tight onto the service hoses (7) and (8), taking care not to mix up the
red and blue markings on the couplings and hoses.
Note
You can look up the current atmospheric pressure for your region on the Internet, for example at
under
air pressure
.
11.
Use the keypad to enter the current local atmospheric pressure and press ENTER to confirm.
12.
When calibration has been completed, press
ENTER
to exit the menu.
13.
Press
STOP
twice to access the standby menu.
14.
To evacuate the service hoses, perform a short vacuum phase (see
on page 20).
14.5 Changing the vacuum pump oil
WARNING! Electrocution hazard
Touching uninsulated parts may result in serious injury. Switch off the
A/C service unit and unplug it from the power supply before opening the housing. the A/C service unit
may only be repaired by personnel authorized by Dometic.
1.
Before changing the oil, let the vacuum pump run for about 10 min (manually, via the menu).
25
Summary of Contents for AirCon ASC 6100G
Page 33: ...English 17 1 Flowchart ASC6100 G Legend 31...
Page 36: ...English 17 2 Circuit diagram ASC6100 G 34...
Page 37: ...English 35...
Page 70: ...French 17 1 Organigramme ASC6100 G L gende 68...
Page 73: ...French 17 2 Sch ma lectrique ASC6100 G 71...
Page 74: ...French 72...
Page 107: ...German 17 1 Flussdiagramm ASC6100 G Legende 105...
Page 110: ...German 17 2 Schaltplan ASC6100 G 108...
Page 111: ...German 109...
Page 113: ...4 4 Tel 49 0 2572 879 0 5 6 Domestic 111...
Page 114: ...Russian 6 1 112...
Page 115: ...Russian 6 2 R1234yf 405 C R134a 743 C R153A 6 3 113...
Page 117: ...10 Dometic 10 10 1 230 V 50 Hz 10 2 10 3 10 4 115...
Page 118: ...11 11 1 2 3 4 5 6 7 USB 116...
Page 119: ...Russian 8 9 10 11 12 117...
Page 124: ...Russian 12 8 8 9 10 12 9 12 2000 g 1 STOP 2 R R1234yf L liquid 122...
Page 137: ...Russian 10 ENTER 11 12 ENTER 13 14 15 D 16 E 17 15 Nm 18 19 20 R1234yf 133 21 133 14 4 135...
Page 139: ...Russian 2 D E 3 I 4 G 5 J 6 J 7 H G 8 9 10 133 14 6 1 2 7783 3 137...
Page 142: ...15 15 ENTER 8 min 50 mbar 120 mbar 134 ENTER 3 136 140...
Page 145: ...Russian 17 1 ASC6100 G 143...
Page 147: ...Russian V1 V2 V3 NCG V4 VC XP XP X3 UV 145...
Page 148: ...Russian 17 2 ASC6100 G 146...
Page 149: ...Russian 147...
Page 183: ...Spanish 17 1 Diagrama de flujo ASC6100 G Leyenda 181...
Page 186: ...Spanish 17 2 Esquema de conexiones ASC6100 G 184...
Page 187: ...Spanish 185...
Page 188: ...4445103553 2022 05 10...