HI 770XHD
Operation
wc_tx001882gb.fm
41
4.7
Connecting and Accessing 120VAC Shore Power
Background
The machine’s 120VAC auxiliary outlet
(a)
is fed by the 120VAC input point
(b)
on
the outside wall of the machine.
Extension
cords
Restrictions for extension cords:
Use only 3-wire type extension cords with heavy-duty plugs.
The maximum length of extension cord usage per circuit is 30 m (100 ft).
Use 12-gauge extension cords for lengths up to 15 m (50 ft).
Use 10-gauge extension cords for lengths up to 30 m (100 ft).
Procedure
1. Place the outlet breaker
(c)
in the ON position.
2. Connect the 120VAC supply extension cord to the 120VAC input point
(b)
.
3. Connect the engine block heater or other 120VAC device to the 120VAC
auxiliary outlet
(a)
.
wc_gr008667
b
wc_gr008668
a
WARNING
Fire hazard and electric shock hazard. The use of undersized extension cords can
lead to fire and electric shock. Fire and electric shock can cause severe injury.
f
Do not use undersized extension cords.
wc_gr008673
OUTLET
c