Labels
HI 770XHD
22
wc_si000622gb.fm
53
After burner shutdown, run blower until
temperature controller reads 37.7° C (100°
F) or lower.
64
Machine weight
65
Important:
Allow blower to run after burner is shut
down, to cool heat exchanger until
temperature control reads 37.7°C
(100°F) or lower.
Failure to do so could cause overheating
and failure of critical components.
80
HI 770XHD OPERATING GUIDE
NOTE: These instructions are intended to provide experienced operators quick
reminders of starting and shutdown procedures explained in detail in the
OPERATOR'S MANUAL. The OPERATOR'S MANUAL MUST BE READ and
UNDERSTOOD before operating this heater.
NOTE: These instructions are intended to provide experienced operators quick reminders of starting and shutdown procedures explained
in detail in the OPERATOR'S MANUAL. The OPERATOR'S MANUAL MUST BE READ and UNDERSTOOD before operating this heater.
HI770 XHD OPERATING GUIDE
STARTING GUIDE
1. Verify the following:
a. Fuel tank has adequate fuel.
b. EMERGENCY STOP button left of roller door is pulled OUT.
c. All control panel switches and circuit breakers are OFF.
2. Turn BATTERY switch ON (located beneath 12 VDC PANEL).
3. Turn ignition key switch to GLOW PLUG position. "GENERATOR GLOW
PLUGS" lamp should illuminate. Hold key switch in this position to heat
glow plugs according to guidelines below. If ambient temperatures are:
Above 40°F Hold for 10 seconds
Between 20 - 40°F Hold for 30 seconds
Below 20°F Hold for 60 seconds or more
4. Turn ignition key switch to RUN position.
5. While holding down LOW OIL PRESSURE OVERRIDE switch, turn
ignition key switch to START position. If engine does not
start after cranking for 20 seconds, repeat Steps 2 - 5.
6. Turn all 3 breakers ON: MAIN, BURNER, and OUTLET.
7. Verify TEMPERATURE CONTROL is set to desired output temperature.
8. Turn BLOWER switch ON.
SHUTDOWN GUIDE
1. Turn BURNER switch OFF.
2. IMPORTANT: Allow BLOWER to run after burner has shut down to cool
heat exchanger until TEMPERATURE CONTROL reads 100°F or lower.
3. Turn BLOWER switch OFF.
4. Turn all 3 breakers OFF: MAIN, BURNER, and OUTLET.
5. Turn ignition key switch counterclockwise to OFF.
6. Be sure all interior lights are switched OFF.
7. Turn BATTERY switch OFF (located beneath 12 VDC PANEL).
FOR EMERGENCY SHUTDOWN: Push EMERGENCY STOP button
ADDITIONAL NOTES
1. ALWAYS refer to the OPERATOR'S MANUAL when questions or
abnormal conditions arise.
2. Contact your dealer for any additional support required.
193349
9. Turn BURNER switch ON. Burner motor will start after 5 second
delay and fuel will be ignited after 6 second purge.
NOTE: If the machine has run out of fuel, the prime pump may
need pushing after refueling.
Summary of Contents for HI 770XHD
Page 1: ...5200003388 04 0212 5 2 0 0 0 0 3 3 8 8 Operator s Manual IDF Heater HI 770XHD EN...
Page 8: ...Table of Contents HI 770XHD wc_bo5200003388_04TOC fm 8...
Page 104: ...wc_tx001887gb fm 104 Schematics HI 770XHD 11 Schematics 11 1 AC Circuit...
Page 106: ...wc_tx001887gb fm 106 Schematics HI 770XHD 11 4 DC Circuit...
Page 111: ......