Operation
HI 770XHD
54
wc_tx001882gb.fm
4.18
Stopping the Machine
NOTICE:
Do not use the emergency stop switch to stop the machine in normal
operating circumstances.
Burner and
blower
Perform the procedure below to shut down the burner.
1. Move the burner ON-OFF switch
(a)
to the OFF position.
2. Wait until the temperature controller
(b)
reads 100°F (38°C) or less.
NOTICE:
Do not turn off the blower until the machine cools below 100°F (38°C).
3. When the machine is cool, move the blower ON-OFF switch
(c)
to the OFF
position.
4. Move the burner breaker
(d)
and the main breaker
(e)
switches to the OFF
position.
This procedure continues on the next page.
wc_gr008678
OUTLET
b
a
wc_gr008679
OUTLET
d
e
c
Summary of Contents for HI 770XHD
Page 1: ...5200003388 04 0212 5 2 0 0 0 0 3 3 8 8 Operator s Manual IDF Heater HI 770XHD EN...
Page 8: ...Table of Contents HI 770XHD wc_bo5200003388_04TOC fm 8...
Page 104: ...wc_tx001887gb fm 104 Schematics HI 770XHD 11 Schematics 11 1 AC Circuit...
Page 106: ...wc_tx001887gb fm 106 Schematics HI 770XHD 11 4 DC Circuit...
Page 111: ......