![Wacker Neuson HI 770XHD Operator'S Manual Download Page 101](http://html1.mh-extra.com/html/wacker-neuson/hi-770xhd/hi-770xhd_operators-manual_3137713101.webp)
HI 770XHD
Basic Troubleshooting
wc_tx001886gb.fm
101
Motor overheating
Belt not correctly tightened
Adjust belt tension.
Over or under voltage
Check power supply.
Fan inoperative
Circuit breaker tripped
Reset circuit breaker.
Loose or disconnected wiring
Check wiring and repair as
needed.
Malfunctioning motor
Replace motor.
Broken belt
Replace belt.
Problem / Symptom
Reason
Remedy