7.2
Engine
* After engine has been running under load for 15 minutes.
** Engine oil should be less than 80°C.
*** Including oil cooler, without oil filter.
Engine
Type
Diesel
Make
Deutz
Model
BF4M 2011
Prime rating power at rated
speed
kW
36,4 @ 1500 rpm
Operating Speed
rpm
1500
Cooling system
type
Oil with radiator
Speed
rpm
1500
Displacement
cc
3110
Cylinders
no.
4
Aspiration type
Turbo
Governor
type
Mechanical
Battery
V/cca
12/680
Electrical system (DC)
Volt
12
Oil
type
(SAE)
20 W 20
Oil quantity***
l
13,5
V-belt pretension / tension*
N
450 / 350 ± 20
Valve clearance (cold)**
mm
Inlet: 0.3+.01; outlet: 0.5+.01
Summary of Contents for G 43
Page 1: ...Mobile Generator G 43 OPERATOR S MANUAL 0175257en 001 0608 0 1 7 5 2 5 7 E N...
Page 2: ......
Page 4: ...Foreword G 43 wc_tx000898gb fm 4...
Page 13: ...50Hz Mobile Generators Safety Information wc_si000271gb fm 13 Notes...
Page 18: ...Transporting Lifting and Storing 50Hz Mobile Generators wc_tx000895gb fm 18 Notes...
Page 48: ...Schematics 50Hz Mobile Generators wc_tx000886gb fm 48 5 Schematics 5 1 Power Wiring...
Page 50: ...Schematics 50Hz Mobile Generators wc_tx000886gb fm 50 5 3 Engine Wiring...
Page 52: ...Schematics 50Hz Mobile Generators wc_tx000886gb fm 52 5 5 Socket Wiring...
Page 54: ...Schematics 50Hz Mobile Generators wc_tx000886gb fm 54 5 7 Control Wiring...
Page 57: ...50Hz Mobile Generators Basic Troubleshooting wc_tx000896gb fm 57...
Page 60: ...Technical Data G 43 wc_td000277gb fm 60 7 3 Dimensions...
Page 62: ......
Page 64: ......