![Wacker Neuson E 2200 Operator'S Manual Download Page 89](http://html1.mh-extra.com/html/wacker-neuson/e-2200/e-2200_operators-manual_3127127089.webp)
E 2200, E 3000ES
Burner Setup
wc_tx001669gb.fm
89
6.5
Setting the Fuel Pressure
Requirements
Pressure gauge
See
Factory Settings
chart in topic
Burner Setup
for fuel pressure reading
Procedure
Follow the procedure below to check and adjust the fuel pressure.
1. Shut down the machine.
2. Remove the bleeder valve
(a)
from the fuel pump.
3. Insert the gauge in place of the bleeder valve.
4. If your machine has a generator, start it.
5. Move the Burner ON-OFF switch to the ON position. The burner will go through
a pre-purge cycle. Monitor and make adjustments during the pre-purge cycle.
6. Turn the adjusting screw
(b)
clockwise to increase fuel pressure,
counterclockwise to decrease fuel pressure.
Result
The fuel pressure has now been adjusted.
Summary of Contents for E 2200
Page 1: ...0192779 001 1210 0 1 9 2 7 7 9 Operator s Manual Hydronic Surface Heater E 2200 E 3000ES...
Page 4: ...Foreword 4 wc_tx001665gb fm...
Page 8: ...8 wc_bo0192779en_001TOC fm Table of Contents E 2200 E 3000ES...
Page 19: ...E 2200 E 3000ES Safety Information wc_si000540gb fm 19 Notes...
Page 64: ...Operation E 2200 E 3000ES 64 wc_tx001667gb fm Notes...
Page 90: ...Burner Setup E 2200 E 3000ES 90 wc_tx001669gb fm Notes...
Page 107: ...E 2200 E 3000ES Maintenance wc_tx001670gb fm 107 Notes...
Page 113: ...E 2200 E 3000ES Technical Data wc_td000422gb fm 113 9 4 Dimensions cm in...
Page 124: ...Schematics E 2200 E 3000ES 124 wc_tx001672gb fm 10 Schematics 10 1 Electrical Schematic...
Page 128: ...Schematics E 2200 E 3000ES 128 wc_tx001672gb fm 10 3 Burner System Circuit...
Page 129: ...E 2200 E 3000ES Schematics wc_tx001672gb fm 129 10 4 Circulation System Circuit ghi_gr005662...
Page 130: ...Schematics E 2200 E 3000ES 130 wc_tx001672gb fm 10 5 Rewind System Circuit...
Page 131: ......