E 2200, E 3000ES
Burner Setup
wc_tx001669gb.fm
83
6.2
Replacing the Burner Nozzle
Prerequisites
Power supplies disconnected
Machine cool
Removal
Follow the procedure below to remove the burner nozzle.
1. Disconnect the power supplies.
2. Remove the copper fuel line
(a)
between the fuel pump and the burner housing.
3. Remove the splined knob
(b)
that is seated against the escutcheon plate.
Note:
Handle the splined knob with care. It is easily damaged.
4. Loosen tabs
(c)
and hinge back the igniter cover.
.
5. Disconnect the preheater wiring.
6. Maneuver the electrode-nozzle assembly
(d)
up and out of the burner.
This procedure continues on the next page.
wc_gr008112
d
wc_gr008113
Summary of Contents for E 2200
Page 1: ...0192779 001 1210 0 1 9 2 7 7 9 Operator s Manual Hydronic Surface Heater E 2200 E 3000ES...
Page 4: ...Foreword 4 wc_tx001665gb fm...
Page 8: ...8 wc_bo0192779en_001TOC fm Table of Contents E 2200 E 3000ES...
Page 19: ...E 2200 E 3000ES Safety Information wc_si000540gb fm 19 Notes...
Page 64: ...Operation E 2200 E 3000ES 64 wc_tx001667gb fm Notes...
Page 90: ...Burner Setup E 2200 E 3000ES 90 wc_tx001669gb fm Notes...
Page 107: ...E 2200 E 3000ES Maintenance wc_tx001670gb fm 107 Notes...
Page 113: ...E 2200 E 3000ES Technical Data wc_td000422gb fm 113 9 4 Dimensions cm in...
Page 124: ...Schematics E 2200 E 3000ES 124 wc_tx001672gb fm 10 Schematics 10 1 Electrical Schematic...
Page 128: ...Schematics E 2200 E 3000ES 128 wc_tx001672gb fm 10 3 Burner System Circuit...
Page 129: ...E 2200 E 3000ES Schematics wc_tx001672gb fm 129 10 4 Circulation System Circuit ghi_gr005662...
Page 130: ...Schematics E 2200 E 3000ES 130 wc_tx001672gb fm 10 5 Rewind System Circuit...
Page 131: ......