4. Tighten the hex head screw.
5. Tighten the splined nut.
6. Reconnect the oil connector tube.
Result
The “Z” distance has now been set.
Continue by setting the head position adjusting plate.
Set the head
position
Perform the procedure below to set the head position adjusting plate.
1. Loosen the hex head screw
(b)
.
2. Loosen the splined nut
(a)
. Do not loosen acorn nut
(c)
.
3. Move the nozzle assembly until the burner reference indicator
(d)
lines up with
the number listed in the
Factory Settings
chart in topic
Burner Setup.
4. Tighten both the hex head screw and the splined nut.
5. Mark
(x)
the head position adjusting plate for future reference.
a
c
b
d
wc_gr008106
x
Summary of Contents for E 2200
Page 1: ...0192779 001 1210 0 1 9 2 7 7 9 Operator s Manual Hydronic Surface Heater E 2200 E 3000ES...
Page 4: ...Foreword 4 wc_tx001665gb fm...
Page 8: ...8 wc_bo0192779en_001TOC fm Table of Contents E 2200 E 3000ES...
Page 19: ...E 2200 E 3000ES Safety Information wc_si000540gb fm 19 Notes...
Page 64: ...Operation E 2200 E 3000ES 64 wc_tx001667gb fm Notes...
Page 90: ...Burner Setup E 2200 E 3000ES 90 wc_tx001669gb fm Notes...
Page 107: ...E 2200 E 3000ES Maintenance wc_tx001670gb fm 107 Notes...
Page 113: ...E 2200 E 3000ES Technical Data wc_td000422gb fm 113 9 4 Dimensions cm in...
Page 124: ...Schematics E 2200 E 3000ES 124 wc_tx001672gb fm 10 Schematics 10 1 Electrical Schematic...
Page 128: ...Schematics E 2200 E 3000ES 128 wc_tx001672gb fm 10 3 Burner System Circuit...
Page 129: ...E 2200 E 3000ES Schematics wc_tx001672gb fm 129 10 4 Circulation System Circuit ghi_gr005662...
Page 130: ...Schematics E 2200 E 3000ES 130 wc_tx001672gb fm 10 5 Rewind System Circuit...
Page 131: ......