Accessories
E 2200, E 3000ES
66
wc_tx001668gb.fm
5.2
Connecting the HX 200 or HX 60 HEAT XCHANGER™
Requirements
Machine stopped
One HEAT XCHANGER (HX 60 or HX 200)
Hose: 2 pieces of 5/8-in. ID or 1-in. ID with quick-connect fittings
Limitations
Maximum run (horizontal distance from HX to machine): 228 m (750 ft)
Maximum rise (vertical distance of HX above machine): 76 m (250 ft)
Maximum run at maximum rise: 215 m (707 ft)
Note:
The farther the HX is positioned from the parent machine, the more heat will
be lost through the hose. This may affect HX performance.
NOTICE:
Disconnect both surface heating hose loops before connecting the
HEAT XCHANGER. The HEAT XCHANGER requires all HTF flow from both
pumps to perform at its rated capacity.
Procedure
Perform the procedure below to connect the HEAT XCHANGER to the machine.
1. Stop the parent machine temporarily.
2. Disconnect both surface heating hose loops from the machine before
connecting the HEAT XCHANGER.
This procedure continues on the next page.
0 – 76 m (250 ft)
0 – 228 m (750 ft)
0 – 215 m (707 ft)
wc_gr008096
Summary of Contents for E 2200
Page 1: ...0192779 001 1210 0 1 9 2 7 7 9 Operator s Manual Hydronic Surface Heater E 2200 E 3000ES...
Page 4: ...Foreword 4 wc_tx001665gb fm...
Page 8: ...8 wc_bo0192779en_001TOC fm Table of Contents E 2200 E 3000ES...
Page 19: ...E 2200 E 3000ES Safety Information wc_si000540gb fm 19 Notes...
Page 64: ...Operation E 2200 E 3000ES 64 wc_tx001667gb fm Notes...
Page 90: ...Burner Setup E 2200 E 3000ES 90 wc_tx001669gb fm Notes...
Page 107: ...E 2200 E 3000ES Maintenance wc_tx001670gb fm 107 Notes...
Page 113: ...E 2200 E 3000ES Technical Data wc_td000422gb fm 113 9 4 Dimensions cm in...
Page 124: ...Schematics E 2200 E 3000ES 124 wc_tx001672gb fm 10 Schematics 10 1 Electrical Schematic...
Page 128: ...Schematics E 2200 E 3000ES 128 wc_tx001672gb fm 10 3 Burner System Circuit...
Page 129: ...E 2200 E 3000ES Schematics wc_tx001672gb fm 129 10 4 Circulation System Circuit ghi_gr005662...
Page 130: ...Schematics E 2200 E 3000ES 130 wc_tx001672gb fm 10 5 Rewind System Circuit...
Page 131: ......