Label Meanings
600
—
601
Refer to back of connection box for further
connection details.
602
Stop!
Do not reset (until HTF leak is repaired and
HTF level is restored)
Red “LOW LEVEL FAULT” light on control
panel indicates HTF is below the minimum
operating level.
Follow procedure below to rectify the fault:
1. Shut off burner switch and pump
switch(es).
2. Find and repair the HTF leak.
3. Add HTF to reservoir up to “MIN” level on
HTF sight gauge.
4. Press manual reset button (below).
5. Turn on burner switch.
6. After burner ignites, turn on pump(s) one
at a time.
603
To prevent loss of Heat Transfer Fluid, the fill
valve must remain LOCKED SHUT (closed)
at all times except as directed in the
Operator’s Manual.
Summary of Contents for E 2200
Page 1: ...0192779 001 1210 0 1 9 2 7 7 9 Operator s Manual Hydronic Surface Heater E 2200 E 3000ES...
Page 4: ...Foreword 4 wc_tx001665gb fm...
Page 8: ...8 wc_bo0192779en_001TOC fm Table of Contents E 2200 E 3000ES...
Page 19: ...E 2200 E 3000ES Safety Information wc_si000540gb fm 19 Notes...
Page 64: ...Operation E 2200 E 3000ES 64 wc_tx001667gb fm Notes...
Page 90: ...Burner Setup E 2200 E 3000ES 90 wc_tx001669gb fm Notes...
Page 107: ...E 2200 E 3000ES Maintenance wc_tx001670gb fm 107 Notes...
Page 113: ...E 2200 E 3000ES Technical Data wc_td000422gb fm 113 9 4 Dimensions cm in...
Page 124: ...Schematics E 2200 E 3000ES 124 wc_tx001672gb fm 10 Schematics 10 1 Electrical Schematic...
Page 128: ...Schematics E 2200 E 3000ES 128 wc_tx001672gb fm 10 3 Burner System Circuit...
Page 129: ...E 2200 E 3000ES Schematics wc_tx001672gb fm 129 10 4 Circulation System Circuit ghi_gr005662...
Page 130: ...Schematics E 2200 E 3000ES 130 wc_tx001672gb fm 10 5 Rewind System Circuit...
Page 131: ......