Maintenance
E 2200, E 3000ES
102
wc_tx001670gb.fm
7.9
Cleaning the Turbulators and the Exhaust Ducting
Requirements
Machine shut down
Machine cool
Procedure
Follow the procedure below to clean/change the turbulator tubes.
1. Allow the machine to cool.
2. Remove the nuts
(a)
that secure the flue box door.
3. Open the flue box door
(b)
.
NOTICE:
If the door panel insulation does not open with the door, carefully remove
it from where it is caught on the bolts
(c)
. Inspect all panels for damaged insulation.
Replace all damaged panels.
4. Locate the turbulators housed in the burner tubes.
5. Remove the turbulators
(d)
by pulling the turbulator tab. Replace any turbulator
that is badly eroded.
6. Clean each burner tube with a bottle brush.
7. Vacuum out each burner tube.
WARNING
Burn hazard. The hydronic heater is very hot when the machine is operating. When
hot it can cause severe burns.
f
Allow the machine to cool before performing this procedure.
Summary of Contents for E 2200
Page 1: ...0192779 001 1210 0 1 9 2 7 7 9 Operator s Manual Hydronic Surface Heater E 2200 E 3000ES...
Page 4: ...Foreword 4 wc_tx001665gb fm...
Page 8: ...8 wc_bo0192779en_001TOC fm Table of Contents E 2200 E 3000ES...
Page 19: ...E 2200 E 3000ES Safety Information wc_si000540gb fm 19 Notes...
Page 64: ...Operation E 2200 E 3000ES 64 wc_tx001667gb fm Notes...
Page 90: ...Burner Setup E 2200 E 3000ES 90 wc_tx001669gb fm Notes...
Page 107: ...E 2200 E 3000ES Maintenance wc_tx001670gb fm 107 Notes...
Page 113: ...E 2200 E 3000ES Technical Data wc_td000422gb fm 113 9 4 Dimensions cm in...
Page 124: ...Schematics E 2200 E 3000ES 124 wc_tx001672gb fm 10 Schematics 10 1 Electrical Schematic...
Page 128: ...Schematics E 2200 E 3000ES 128 wc_tx001672gb fm 10 3 Burner System Circuit...
Page 129: ...E 2200 E 3000ES Schematics wc_tx001672gb fm 129 10 4 Circulation System Circuit ghi_gr005662...
Page 130: ...Schematics E 2200 E 3000ES 130 wc_tx001672gb fm 10 5 Rewind System Circuit...
Page 131: ......