FLASHBAKE
®
/ MICROWAVE OVEN REMOVAL AND REPLACEMENT OF PARTS
Form 24694 (April 2001)
Page 21 of 52
MODEL FBMW2 SHOWN
MODEL FBMW3 SHOWN
4.
Remove four screws securing transformer to
base and remove transformer.
5.
Reverse procedure to install.
MAGNETRON
WARNING: DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
NOTE: During reassembly, before installing main
cover and after all necessary components are
replaced and adjusted, a radiation leak test MUST
be performed.
WARNING: DUE TO HIGH VOLTAGE, SPECIAL
CARE SHOULD BE TAKEN WHEN MEASURING
AROUND THE MAGNETRON.
1.
Remove "UPPER LAMP HOUSING AND
DUCT ASSEMBLY.”
2.
Remove "MAGNETRON COOLING FAN.”
3.
Remove two screws securing side panel to
base and let it hang off to the side.
4.
Disconnect lead wires from magnetron
terminals (Model FBMW2).
Disconnect choke filter from magnetron
terminals (Model FBMW3).
5.
Disconnect wire leads from thermal disk.
NOTE: If magnetron is being replaced, remove
screw securing disk bracket and lay bracket with
disk aside.