— 6 —
C24EO SERIES STEAMER
LOCATION
The installation location must allow adequate
clearances for servicing and proper operation.
Minimum clearance for proper air circulation is
2" (5.1 cm) on the sides and 6" (15.2 cm) on
the back.
LEVELING FEET
This steamer is shipped with four 2" leveling
feet. Optional 4" leveling feet are available.
The 2" feet can be removed and the optional 4"
feet can be threaded into holes on the bottom
of the unit.
LEVELING
Position and level the unit using leveling feet.
Front of unit should be
1
/
16
" to
1
/
8
" higher than
the rear as indicated in Figure 1. Unit should be
level side to side.
Level the steamer front to back and side to side
by turning the adjustable feet.
Figure 1: Leveling Steamer
ANCHORING STEAMER
1. Place steamer in the desired location on
the countertop and mark four corners.
Remove the steamer and drill
1
/
2
" holes as
indicated in Figure 2.
2. Apply a bead of RTV or other NSF approved
sealant around the bottom edge of the
steamer. If anchoring the steamer, this
bottom seal is necessary to meet NSF
requirements.
3. Set steamer on countertop and bolt down
securely with
3
/
8
" by 16" bolts (not supplied).
Screw length should be tabletop thickness
plus
1
/
2
" for proper thread engagement.
Figure 2: Anchoring Steamer
OPTIONAL ACCESSORIES
Optional accessories such as stands and
stacking kit will include directions for
assembly.