![Vulcan-Hart C24EO3 Installation & Operation Manual Download Page 8](http://html1.mh-extra.com/html/vulcan-hart/c24eo3/c24eo3_installation-and-operation-manual_1056867008.webp)
— 8 —
C24EO SERIES STEAMER
ELECTRICAL DATA
Model
Volts KW
Amp @
1PH
Amp @
3 PH
C24EO3
208
8
38.5
22.2
240
8
33.3
19.2
C24EO5
208
12
57.7
33.3
240
12
50.0
28.9
480
12
N/A
14.4
SERVICE CONNECTIONS
Water Connections (Manual Fill Units)
No water supply connections are required, as
the steamer is fi lled manually.
Water Connections (Auto-Fill Units)
NOTE:
Auto-Fill steamers will refi ll automatically
if the water level is low.
Connect the cold water supply line to the 3/4"
(19 mm) (male hose thread) inlet.
A manual shutoff valve must be provided in a
convenient location near the steamer.
The incoming water pressure must be 20 - 60
psig.
Cold Water
Connection
Water Requirements
Proper water quality can improve the taste
of the food prepared in the steamer, reduce
liming in the steam generator and extend
equipment life. Water conditions vary from one
location to another. Presence of iron content,
amount of chloridation and dissolved gases could
aff ect the taste. Adding a carbon block fi lter to
the water inlet will improve taste.
Drain Connection
The C24EO can be confi gured to drain through
either the rear panel or through the bottom base
plate.
The unit is confi gured to be drained through the
rear panel from the factory. The unit is supplied
with a 12" length of
5
/
8
" ID hose. If this length is
insuffi cient, remove the hose and install a new
hose ordered to the desired length. The factory
5
/
8
" ID silicone hose part number is 557475. Hose
is sold by the foot.
See Figure 3.
Figure 3: Rear Panel Drain Connection
(Viewed with right side panel removed)
To fi eld confi gure the drain through the bottom
base plate, the 4" leg kit (part number 843889) is
required. Also required are a
1
/
2
" NPT close pipe
nipple (1
1
/
8
" long) and a
1
/
2
" NPT 90° elbow, which
are available through local home improvement
or plumbing supply houses.
1. Remove right side panel.
2. Remove hose barb from drain.
3. Remove knockout from base plate.