De-stoning machine EP 1000
Version: 136401000_M0014772F_EN400/50D
Datum: 15.01.2021
- 16 / 40 -
3.2 Notes on installation
NOTE!
It has to be on a horizontal installation of the machine / unit!
INFORMATION!
Non-slip, waterproof footwear is recommended
NOTE!
There’s no separate light mounted on the unit.
The licensee is responsible for adequate light based on national requirements for workplace layout!
3.3 Notes on assembly
WARNING OF DANGEROUS LIVE ELECTRICAL POWER SUPPLY
The Power connection must not come into contact with water!
Not observing this requirement can lead to serious injury or to death!
NOTE!
- It must be ensured that the machine is set up in a level position!
- The mains connection cables must be kept clear of the machine/line working area !
-
Mobile devices that are used in the open air must be connected with minimum
operational
current switch protection (FI)
.
If this is not possible, the machine must be
grounded separately.
The stone removal system may only be connected to 400 V lines that are protected by a circuit
breaker with a maximum of 16 A.
NOTE!
- The service connections may only be made by appropriately qualified service
companies!
- Only use connection pipes of at least 4 x 2.5 mm² (5 x 2.5 mm²).