Instrument panel, left
Immobiliser System (optional equipment)
NOTE!
The machine can be equipped with an Immobiliser
System with keypad or an Immobiliser Antenna
System at ignition (see page
38
).
1. Keypad
LED
Shows system status by flash codes
(see table below)
9
0
Number keys to enter codes
F1
Function key 1
F2
Function key 2
MD
MD key to enter Codes
Arrow key
EXT
Exit key
ENT
Enter key
2. LED flash codes
No.
Status
Flash Code
Cyclic
0
disarmed
on for 3 s.
no
1
armed
flashes every 0.5 s. for 60 s.
2
code stored/accepted
2 flashes
3
code already in memory / program mode
canceled
3 flashes
yes
4
program mode
no
5a
code failure
5 f 4 flashes
yes
5b
4 flashes
6
timeout
5 flashes
no
7
memory full
6 flashes
8
all codes deleted
7 flashes
yes
9
memory empty
flash every 0.1 s.
10
factory mode
flash every 0.5 s.
11
monitoring mode
flash every 1 s.
3. Concept
The Immobiliser System is delivered without Master
or User Codes.
The 6-digit Master Code must be programmed to
activate the system (follow item 4).
Instrument panels
Instrument panel, left
31
Summary of Contents for EC15E
Page 6: ......
Page 10: ......
Page 237: ......