9-15
Figure 41: Cutter Drive Parts
To re-install the breaker cutter and bearing, follow steps 1-8 below:
1.
Push the new bearing into the cutter support hub.
2.
Using the pin hole in the side of the cutter support hub as a guide, drill a 3/16-in. (5-mm) hole through
the wall of the bearing.
3.
Drive in the 3/16-in. (5-mm) pin through the drilled hole until it is flush with the outside wall of the
cutter support hub. Check that the pin does not extend into the surface inner diameter (ID) of the
bearing.
4.
Slide the new bearing and cutter support onto the cutter shaft and check that it spins freely. If the fit is
tight, carefully ream the inner surface (ID) of the bearing until it turns freely.
5.
Install the bearing support in the water tank, using the reference marks you made as a guide.