-8-
2. WM-1500~2500HZD cabinet installation
•
Cut a rectangular inside opening with the 1/4” clearance inwards to the width and
height of the
cooling unit. By not going through, leave 1/2” lip inside at the wall to
place the gaskets (see Fig 2.1).
•
If top exhaust installation, cut another rectangular opening at the top of the cabinet
to the length and width of the top exhaust.
•
Install 2 pieces of
1/4” ID wood thread inserts at the ceiling (see Fig.2.1 & 2.2).
•
Place the gaskets
(1/2” foam tape) on the mounting lip sides (see Fig 2.3).
•
If top exhaust installation, place another gaskets along the top exhaust at the top
of the cooling unit (see Fig.2.4).
•
Move the cooling unit towards the mounting sides and push to press the
gaskets (see Fig 2.5).
•
Use 2 brackets and
¼” screws with 7/16” wrench to secure the cooling unit
(see Fig 2.6).
•
Install the cabinet grille on the cabinet exterior wall (see Fig. 2.7).
•
Plug the cooling unit in the cabinet receptacle.
•
Plug the wine cabinet.
Fig. 2.1 CABINET CUTOUT & GASKET LIP
Summary of Contents for WINE-MATE WM-1500HZD
Page 6: ... 5 Fig 1 2 WM 3500 8500HZD FEATURE DESCRIPTIONS Fig 1 3 WM 1500 2500HZD DIMENSIONS ...
Page 10: ... 9 Fig 2 2 THREAD INSERT Fig 2 3 REAR GASKET ...
Page 11: ... 10 Fig 2 4 TOP EXHAUST GASKET Fig 2 5 COOLING UNIT MOUNTING ...
Page 12: ... 11 Fig 2 6 SECURING BRACKET SCREW ...
Page 13: ... 12 Fig 2 7 CABINET GRILLE ...
Page 25: ... 23 12 Temperature a Low temperature setting a Raise the setting ...
Page 28: ... 26 Fig 6 3 WM 3500 8500HZD WIRING DIAGRAM Fig 6 4 WM 3500 8500HZD WIRING DIAGRAM ALARM CALL ...