-7-
Installation Instructions
WARNING
•
Always check wiring harness connections before initiating any test procedures.
•
Disconnect electric power from the appliance before performing any
maintenance or repairs.
•
Voltage checks should be made by inserting meter proves beside the wires in
the connector blocks with the electric power source on and the connector block
plugged in.
•
Resistance checks should be made on components with the electric power off
and the connector block disconnected.
NOTES:
•
Mounting brackets, screws, gaskets and other seal materials are not included.
•
Do not install any ducts onto the supply, return, intake and exhaust.
•
Because of potential safety hazards under a certain condition we strongly
recommend against the use of an extension cord. However, if you still select to
use an extension cord, it is absolutely necessary that it is a UL LISTED 3- wire
grounding type appliance extension cord having a 3-blade grounding plug
and a 3-slot receptacle that will plug into the appliance. The marked rating of
the extension cord shall be 115 V, 15 A or equivalent for WM- 1500~2500HZD
and 115 V, 20 A or equivalent for WM-3500~8500HZD and not greater than
15ft in length.
1. General Instructions
•
The cooling unit produces cooling supplied into the cellar, meanwhile it also
generates heat that must be exhausted outside the cellar. So the cold- air supply
with return-air intake side and the hot-air exhaust with ambient-air intake side must
be separated and sealed. Through-wall installations can separate these two sides.
•
Furthermore, the condenser of cooling unit must intake adequate fresh ambient-
air to work properly. The ambient-air intake and hot-air exhaust must not be short-
circulated. Both of them must remain unobstructed 36” clearance all around. The
area into which the hot air is exhausted must be well ventilated. If it is not, heat
generated by the unit will build up and the unit will not operate properly.
•
Additionally, cold-
air supply from the front grille must remain unobstructed 36”
clearance.
•
The ambient temperatures shall not be above and below what are specified.
Summary of Contents for WINE-MATE WM-1500HZD
Page 6: ... 5 Fig 1 2 WM 3500 8500HZD FEATURE DESCRIPTIONS Fig 1 3 WM 1500 2500HZD DIMENSIONS ...
Page 10: ... 9 Fig 2 2 THREAD INSERT Fig 2 3 REAR GASKET ...
Page 11: ... 10 Fig 2 4 TOP EXHAUST GASKET Fig 2 5 COOLING UNIT MOUNTING ...
Page 12: ... 11 Fig 2 6 SECURING BRACKET SCREW ...
Page 13: ... 12 Fig 2 7 CABINET GRILLE ...
Page 25: ... 23 12 Temperature a Low temperature setting a Raise the setting ...
Page 28: ... 26 Fig 6 3 WM 3500 8500HZD WIRING DIAGRAM Fig 6 4 WM 3500 8500HZD WIRING DIAGRAM ALARM CALL ...